Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Interface Focus ; 13(6): 20230038, 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38106921

RESUMO

To enable large in silico trials and personalized model predictions on clinical timescales, it is imperative that models can be constructed quickly and reproducibly. First, we aimed to overcome the challenges of constructing cardiac models at scale through developing a robust, open-source pipeline for bilayer and volumetric atrial models. Second, we aimed to investigate the effects of fibres, fibrosis and model representation on fibrillatory dynamics. To construct bilayer and volumetric models, we extended our previously developed coordinate system to incorporate transmurality, atrial regions and fibres (rule-based or data driven diffusion tensor magnetic resonance imaging (MRI)). We created a cohort of 1000 biatrial bilayer and volumetric models derived from computed tomography (CT) data, as well as models from MRI, and electroanatomical mapping. Fibrillatory dynamics diverged between bilayer and volumetric simulations across the CT cohort (correlation coefficient for phase singularity maps: left atrial (LA) 0.27 ± 0.19, right atrial (RA) 0.41 ± 0.14). Adding fibrotic remodelling stabilized re-entries and reduced the impact of model type (LA: 0.52 ± 0.20, RA: 0.36 ± 0.18). The choice of fibre field has a small effect on paced activation data (less than 12 ms), but a larger effect on fibrillatory dynamics. Overall, we developed an open-source user-friendly pipeline for generating atrial models from imaging or electroanatomical mapping data enabling in silico clinical trials at scale (https://github.com/pcmlab/atrialmtk).

2.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37421339

RESUMO

AIMS: Substrate assessment of scar-mediated ventricular tachycardia (VT) is frequently performed using late gadolinium enhancement (LGE) images. Although this provides structural information about critical pathways through the scar, assessing the vulnerability of these pathways for sustaining VT is not possible with imaging alone.This study evaluated the performance of a novel automated re-entrant pathway finding algorithm to non-invasively predict VT circuit and inducibility. METHODS: Twenty post-infarct VT-ablation patients were included for retrospective analysis. Commercially available software (ADAS3D left ventricular) was used to generate scar maps from 2D-LGE images using the default 40-60 pixel-signal-intensity (PSI) threshold. In addition, algorithm sensitivity for altered thresholds was explored using PSI 45-55, 35-65, and 30-70. Simulations were performed on the Virtual Induction and Treatment of Arrhythmias (VITA) framework to identify potential sites of block and assess their vulnerability depending on the automatically computed round-trip-time (RTT). Metrics, indicative of substrate complexity, were correlated with VT-recurrence during follow-up. RESULTS: Total VTs (85 ± 43 vs. 42 ± 27) and unique VTs (9 ± 4 vs. 5 ± 4) were significantly higher in patients with- compared to patients without recurrence, and were predictive of recurrence with area under the curve of 0.820 and 0.770, respectively. VITA was robust to scar threshold variations with no significant impact on total and unique VTs, and mean RTT between the four models. Simulation metrics derived from PSI 45-55 model had the highest number of parameters predictive for post-ablation VT-recurrence. CONCLUSION: Advanced computational metrics can non-invasively and robustly assess VT substrate complexity, which may aid personalized clinical planning and decision-making in the treatment of post-infarction VT.


Assuntos
Cicatriz , Simulação por Computador , Taquicardia Ventricular , Humanos , Algoritmos , Ablação por Cateter , Cicatriz/complicações , Infarto do Miocárdio/complicações , Estudos Retrospectivos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Reprodutibilidade dos Testes , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais
3.
J Cardiovasc Electrophysiol ; 34(4): 984-993, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36738149

RESUMO

INTRODUCTION: Conduction system pacing (CSP), in the form of His bundle pacing (HBP) or left bundle branch pacing (LBBP), is emerging as a valuable cardiac resynchronization therapy (CRT) delivery method. However, patient selection and therapy personalization for CSP delivery remain poorly characterized. We aim to compare pacing-induced electrical synchrony during CRT, HBP, LBBP, HBP with left ventricular (LV) epicardial lead (His-optimized CRT [HOT-CRT]), and LBBP with LV epicardial lead (LBBP-optimized CRT [LOT-CRT]) in patients with different conduction disease presentations using computational modeling. METHODS: We simulated ventricular activation on 24 four-chamber heart geometries, including His-Purkinje systems with proximal left bundle branch block (LBBB). We simulated septal scar, LV lateral wall scar, and mild and severe myocardium and LV His-Purkinje system conduction disease by decreasing the conduction velocity (CV) down to 70% and 35% of the healthy CV. Electrical synchrony was measured by the shortest interval to activate 90% of the ventricles (90% of biventricular activation time [BIVAT-90]). RESULTS: Severe LV His-Purkinje conduction disease favored CRT (BIVAT-90: HBP 101.5 ± 7.8 ms vs. CRT 93.0 ± 8.9 ms, p < .05), with additional electrical synchrony induced by HOT-CRT (87.6 ± 6.7 ms, p < .05) and LOT-CRT (73.9 ± 7.6 ms, p < .05). Patients with slow myocardium CV benefit more from CSP compared to CRT (BIVAT-90: CRT 134.5 ± 24.1 ms; HBP 97.1 ± 9.9 ms, p < .01; LBBP: 101.5 ± 10.7 ms, p < .01). Septal but not lateral wall scar made CSP ineffective, while CRT was able to resynchronize the ventricles in the presence of septal scar (BIVAT-90: baseline 119.1 ± 10.8 ms vs. CRT 85.1 ± 14.9 ms, p < .01). CONCLUSION: Severe LV His-Purkinje conduction disease attenuates the benefits of CSP, with additional improvements achieved with HOT-CRT and LOT-CRT. Septal but not lateral wall scars make CSP ineffective.


Assuntos
Fascículo Atrioventricular , Cicatriz , Humanos , Eletrocardiografia/métodos , Sistema de Condução Cardíaco , Miocárdio
4.
Front Physiol ; 13: 1011566, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36213223

RESUMO

A significant number of right bundle branch block (RBBB) patients receive cardiac resynchronization therapy (CRT), despite lack of evidence for benefit in this patient group. His bundle (HBP) and left bundle pacing (LBP) are novel CRT delivery methods, but their effect on RBBB remains understudied. We aim to compare pacing-induced electrical synchrony during conventional CRT, HBP, and LBP in RBBB patients with different conduction disturbances, and to investigate whether alternative ways of delivering LBP improve response to pacing. We simulated ventricular activation on twenty-four four-chamber heart geometries each including a His-Purkinje system with proximal right bundle branch block (RBBB). We simulated RBBB combined with left anterior and posterior fascicular blocks (LAFB and LPFB). Additionally, RBBB was simulated in the presence of slow conduction velocity (CV) in the myocardium, left ventricular (LV) or right ventricular (RV) His-Purkinje system, and whole His-Purkinje system. Electrical synchrony was measured by the shortest interval to activate 90% of the ventricles (BIVAT-90). Compared to baseline, HBP significantly improved activation times for RBBB alone (BIVAT-90: 66.9 ± 5.5 ms vs. 42.6 ± 3.8 ms, p < 0.01), with LAFB (69.5 ± 5.0 ms vs. 58.1 ± 6.2 ms, p < 0.01), with LPFB (81.8 ± 6.6 ms vs. 62.9 ± 6.2 ms, p < 0.01), with slow myocardial CV (119.4 ± 11.4 ms vs. 97.2 ± 10.0 ms, p < 0.01) or slow CV in the whole His-Purkinje system (102.3 ± 7.0 ms vs. 75.5 ± 5.2 ms, p < 0.01). LBP was only effective in RBBB cases if combined with anodal capture of the RV septum myocardium (BIVAT-90: 66.9 ± 5.5 ms vs. 48.2 ± 5.2 ms, p < 0.01). CRT significantly reduced activation times in RBBB in the presence of severely slow RV His-Purkinje CV (95.1 ± 7.9 ms vs. 84.3 ± 9.3 ms, p < 0.01) and LPFB (81.8 ± 6.6 ms vs. CRT: 72.9 ± 8.6 ms, p < 0.01). Both CRT and HBP were ineffective with severely slow CV in the LV His-Purkinje system. HBP is effective in RBBB patients with otherwise healthy myocardium and Purkinje system, while CRT and LBP are ineffective. Response to LBP improves when LBP is combined with RV septum anodal capture. CRT is better than HBP only in patients with severely slow CV in the RV His-Purkinje system, while CV slowing of the whole His-Purkinje system and the myocardium favor HBP over CRT.

5.
Front Physiol ; 13: 907190, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36213235

RESUMO

Computer models capable of representing the intrinsic personal electrophysiology (EP) of the heart in silico are termed virtual heart technologies. When anatomy and EP are tailored to individual patients within the model, such technologies are promising clinical and industrial tools. Regardless of their vast potential, few virtual technologies simulating the entire organ-scale EP of all four-chambers of the heart have been reported and widespread clinical use is limited due to high computational costs and difficulty in validation. We thus report on the development of a novel virtual technology representing the electrophysiology of all four-chambers of the heart aiming to overcome these limitations. In our previous work, a model of ventricular EP embedded in a torso was constructed from clinical magnetic resonance image (MRI) data and personalized according to the measured 12 lead electrocardiogram (ECG) of a single subject under normal sinus rhythm. This model is then expanded upon to include whole heart EP and a detailed representation of the His-Purkinje system (HPS). To test the capacities of the personalized virtual heart technology to replicate standard clinical morphological ECG features under such conditions, bundle branch blocks within both the right and the left ventricles under two different conduction velocity settings are modeled alongside sinus rhythm. To ensure clinical viability, model generation was completely automated and simulations were performed using an efficient real-time cardiac EP simulator. Close correspondence between the measured and simulated 12 lead ECG was observed under normal sinus conditions and all simulated bundle branch blocks manifested relevant clinical morphological features.

6.
Med Image Anal ; 80: 102483, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35667328

RESUMO

Catheter ablation is currently the only curative treatment for scar-related ventricular tachycardias (VTs). However, not only are ablation procedures long, with relatively high risk, but success rates are punitively low, with frequent VT recurrence. Personalized in-silico approaches have the opportunity to address these limitations. However, state-of-the-art reaction diffusion (R-D) simulations of VT induction and subsequent circuits used for in-silico ablation target identification require long execution times, along with vast computational resources, which are incompatible with the clinical workflow. Here, we present the Virtual Induction and Treatment of Arrhythmias (VITA), a novel, rapid and fully automated computational approach that uses reaction-Eikonal methodology to induce VT and identify subsequent ablation targets. The rationale for VITA is based on finding isosurfaces associated with an activation wavefront that splits in the ventricles due to the presence of an isolated isthmus of conduction within the scar; once identified, each isthmus may be assessed for their vulnerability to sustain a reentrant circuit, and the corresponding exit site automatically identified for potential ablation targeting. VITA was tested on a virtual cohort of 7 post-infarcted porcine hearts and the results compared to R-D simulations. Using only a standard desktop machine, VITA could detect all scar-related VTs, simulating activation time maps and ECGs (for clinical comparison) as well as computing ablation targets in 48 minutes. The comparable VTs probed by the R-D simulations took 68.5 hours on 256 cores of high-performance computing infrastructure. The set of lesions computed by VITA was shown to render the ventricular model VT-free. VITA could be used in near real-time as a complementary modality aiding in clinical decision-making in the treatment of post-infarction VTs.


Assuntos
Ablação por Cateter , Infarto do Miocárdio , Taquicardia Ventricular , Animais , Arritmias Cardíacas/cirurgia , Cicatriz , Eletrocardiografia , Humanos , Suínos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia
7.
Heart Rhythm ; 19(10): 1604-1610, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35644355

RESUMO

BACKGROUND: Thresholding-based analysis of late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) can create scar maps and identify corridors that might provide a reentrant substrate for ventricular tachycardia (VT). Current recommendations use a full-width-at-half-maximum approach, effectively classifying areas with a pixel signal intensity (PSI) >40% as border zone (BZ) and >60% as core. OBJECTIVE: The purpose of this study was to investigate the impact of 4 different threshold settings on scar and corridor quantification and to correlate this with postablation VT recurrence. METHODS: Twenty-seven patients with ischemic cardiomyopathy who had undergone catheter ablation for VT were included for retrospective analysis. LGE-CMR images were analyzed using ADAS3D LV. Scar maps were created for 4 PSI thresholds (40-60, 35-65, 30-70, and 45-55), and the extent of variation in BZ and core, as well as the number and weight of conduction corridors, were quantified. Three-dimensional representations were reconstructed from exported segmentations and used to quantify the surface area between healthy myocardium and scar (BZ + core), and between BZ and core. RESULTS: A wider PSI threshold was associated with an increase in BZ mass and decrease in scar (P <.001). No significant differences were observed for the total number of corridors and their mass with increasing PSI threshold. The best correlation in predicting arrhythmia recurrence was observed for PSI 45-55 (area under the curve 0.807; P = .001). CONCLUSION: Varying PSI has a significant impact on quantification of LGE-CMR parameters and may have incremental clinical value in predicting arrhythmia recurrence. Further prospective investigation is warranted to clarify the functional implications of these findings for LGE-CMR-guided ventricular ablation.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Ablação por Cateter/métodos , Cicatriz/diagnóstico , Cicatriz/etiologia , Cicatriz/patologia , Meios de Contraste/farmacologia , Gadolínio/farmacologia , Humanos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Estudos Retrospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/patologia , Taquicardia Ventricular/cirurgia
8.
Am J Physiol Heart Circ Physiol ; 322(6): H936-H952, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35302879

RESUMO

Cardiac fiber direction is an important factor determining the propagation of electrical activity, as well as the development of mechanical force. In this article, we imaged the ventricles of several species with special attention to the intraventricular septum to determine the functional consequences of septal fiber organization. First, we identified a dual-layer organization of the fiber orientation in the intraventricular septum of ex vivo sheep hearts using diffusion tensor imaging at high field MRI. To expand the scope of the results, we investigated the presence of a similar fiber organization in five mammalian species (rat, canine, pig, sheep, and human) and highlighted the continuity of the layer with the moderator band in large mammalian species. We implemented the measured septal fiber fields in three-dimensional electromechanical computer models to assess the impact of the fiber orientation. The downward fibers produced a diamond activation pattern superficially in the right ventricle. Electromechanically, there was very little change in pressure volume loops although the stress distribution was altered. In conclusion, we clarified that the right ventricular septum has a downwardly directed superficial layer in larger mammalian species, which can have modest effects on stress distribution.NEW & NOTEWORTHY A dual-layer organization of the fiber orientation in the intraventricular septum was identified in ex vivo hearts of large mammals. The RV septum has a downwardly directed superficial layer that is continuous with the moderator band. Electrically, it produced a diamond activation pattern. Electromechanically, little change in pressure volume loops were noticed but stress distribution was altered. Fiber distribution derived from diffusion tensor imaging should be considered for an accurate strain and stress analysis.


Assuntos
Imagem de Tensor de Difusão , Septo Interventricular , Animais , Diamante , Cães , Ventrículos do Coração , Mamíferos , Miocárdio , Ratos , Ovinos , Suínos , Septo Interventricular/diagnóstico por imagem
9.
Front Physiol ; 13: 1049214, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36589454

RESUMO

Biventricular endocardial (BIV-endo) pacing and left bundle pacing (LBP) are novel delivery methods for cardiac resynchronization therapy (CRT). Both pacing methods can be delivered through leadless pacing, to avoid risks associated with endocardial or transvenous leads. We used computational modelling to quantify synchrony induced by BIV-endo pacing and LBP through a leadless pacing system, and to investigate how the right-left ventricle (RV-LV) delay, RV lead location and type of left bundle capture affect response. We simulated ventricular activation on twenty-four four-chamber heart meshes inclusive of His-Purkinje networks with left bundle branch block (LBBB). Leadless biventricular (BIV) pacing was simulated by adding an RV apical stimulus and an LV lateral wall stimulus (BIV-endo lateral) or targeting the left bundle (BIV-LBP), with an RV-LV delay set to 5 ms. To test effect of prolonged RV-LV delays and RV pacing location, the RV-LV delay was increased to 35 ms and/or the RV stimulus was moved to the RV septum. BIV-endo lateral pacing was less sensitive to increased RV-LV delays, while RV septal pacing worsened response compared to RV apical pacing, especially for long RV-LV delays. To investigate how left bundle capture affects response, we computed 90% BIV activation times (BIVAT-90) during BIV-LBP with selective and non-selective capture, and left bundle branch area pacing (LBBAP), simulated by pacing 1 cm below the left bundle. Non-selective LBP was comparable to selective LBP. LBBAP was worse than selective LBP (BIVAT-90: 54.2 ± 5.7 ms vs. 62.7 ± 6.5, p < 0.01), but it still significantly reduced activation times from baseline. Finally, we compared leadless LBP with RV pacing against optimal LBP delivery through a standard lead system by simulating BIV-LBP and selective LBP alone with and without optimized atrioventricular delay (AVD). Although LBP alone with optimized AVD was better than BIV-LBP, when AVD optimization was not possible BIV-LBP outperformed LBP alone, because the RV pacing stimulus shortened RV activation (BIVAT-90: 54.2 ± 5.7 ms vs. 66.9 ± 5.1 ms, p < 0.01). BIV-endo lateral pacing or LBP delivered through a leadless system could potentially become an alternative to standard CRT. RV-LV delay, RV lead location and type of left bundle capture affect leadless pacing efficacy and should be considered in future trial designs.

10.
Comput Biol Med ; 141: 105061, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34915331

RESUMO

BACKGROUND: Computational models of the heart built from cardiac MRI and electrophysiology (EP) data have shown promise for predicting the risk of and ablation targets for myocardial infarction (MI) related ventricular tachycardia (VT), as well as to predict paced activation sequences in heart failure patients. However, most recent studies have relied on low resolution imaging data and little or no EP personalisation, which may affect the accuracy of model-based predictions. OBJECTIVE: To investigate the impact of model anatomy, MI scar morphology, and EP personalisation strategies on paced activation sequences and VT inducibility to determine the level of detail required to make accurate model-based predictions. METHODS: Imaging and EP data were acquired from a cohort of six pigs with experimentally induced MI. Computational models of ventricular anatomy, incorporating MI scar, were constructed including bi-ventricular or left ventricular (LV) only anatomy, and MI scar morphology with varying detail. Tissue conductivities and action potential duration (APD) were fitted to 12-lead ECG data using the QRS duration and the QT interval, respectively, in addition to corresponding literature parameters. Paced activation sequences and VT induction were simulated. Simulated paced activation and VT inducibility were compared between models and against experimental data. RESULTS: Simulations predict that the level of model anatomical detail has little effect on simulated paced activation, with all model predictions comparing closely with invasive EP measurements. However, detailed scar morphology from high-resolution images, bi-ventricular anatomy, and personalized tissue conductivities are required to predict experimental VT outcome. CONCLUSION: This study provides clear guidance for model generation based on clinical data. While a representing high level of anatomical and scar detail will require high-resolution image acquisition, EP personalisation based on 12-lead ECG can be readily incorporated into modelling pipelines, as such data is widely available.


Assuntos
Infarto do Miocárdio , Taquicardia Ventricular , Animais , Eletrocardiografia , Coração , Ventrículos do Coração/diagnóstico por imagem , Humanos , Infarto do Miocárdio/diagnóstico por imagem , Suínos , Taquicardia Ventricular/diagnóstico por imagem
11.
Ann Biomed Eng ; 49(12): 3143-3153, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34431016

RESUMO

Personalized models of cardiac electrophysiology (EP) that match clinical observation with high fidelity, referred to as cardiac digital twins (CDTs), show promise as a tool for tailoring cardiac precision therapies. Building CDTs of cardiac EP relies on the ability of models to replicate the ventricular activation sequence under a broad range of conditions. Of pivotal importance is the His-Purkinje system (HPS) within the ventricles. Workflows for the generation and incorporation of HPS models are needed for use in cardiac digital twinning pipelines that aim to minimize the misfit between model predictions and clinical data such as the 12 lead electrocardiogram (ECG). We thus develop an automated two stage approach for HPS personalization. A fascicular-based model is first introduced that modulates the endocardial Purkinje network. Only emergent features of sites of earliest activation within the ventricular myocardium and a fast-conducting sub-endocardial layer are accounted for. It is then replaced by a topologically realistic Purkinje-based representation of the HPS. Feasibility of the approach is demonstrated. Equivalence between both HPS model representations is investigated by comparing activation patterns and 12 lead ECGs under both sinus rhythm and right-ventricular apical pacing. Predominant ECG morphology is preserved by both HPS models under sinus conditions, but elucidates differences during pacing.


Assuntos
Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Modelos Cardiovasculares , Medicina de Precisão , Algoritmos , Fascículo Atrioventricular/fisiopatologia , Eletrocardiografia , Humanos , Imageamento por Ressonância Magnética , Ramos Subendocárdicos/fisiopatologia
12.
Comput Methods Programs Biomed ; 208: 106223, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34171774

RESUMO

BACKGROUND AND OBJECTIVE: Cardiac electrophysiology is a medical specialty with a long and rich tradition of computational modeling. Nevertheless, no community standard for cardiac electrophysiology simulation software has evolved yet. Here, we present the openCARP simulation environment as one solution that could foster the needs of large parts of this community. METHODS AND RESULTS: openCARP and the Python-based carputils framework allow developing and sharing simulation pipelines which automate in silico experiments including all modeling and simulation steps to increase reproducibility and productivity. The continuously expanding openCARP user community is supported by tailored infrastructure. Documentation and training material facilitate access to this complementary research tool for new users. After a brief historic review, this paper summarizes requirements for a high-usability electrophysiology simulator and describes how openCARP fulfills them. We introduce the openCARP modeling workflow in a multi-scale example of atrial fibrillation simulations on single cell, tissue, organ and body level and finally outline future development potential. CONCLUSION: As an open simulator, openCARP can advance the computational cardiac electrophysiology field by making state-of-the-art simulations accessible. In combination with the carputils framework, it offers a tailored software solution for the scientific community and contributes towards increasing use, transparency, standardization and reproducibility of in silico experiments.


Assuntos
Técnicas Eletrofisiológicas Cardíacas , Software , Simulação por Computador , Humanos , Reprodutibilidade dos Testes , Fluxo de Trabalho
13.
Med Image Anal ; 71: 102080, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33975097

RESUMO

Cardiac digital twins (Cardiac Digital Twin (CDT)s) of human electrophysiology (Electrophysiology (EP)) are digital replicas of patient hearts derived from clinical data that match like-for-like all available clinical observations. Due to their inherent predictive potential, CDTs show high promise as a complementary modality aiding in clinical decision making and also in the cost-effective, safe and ethical testing of novel EP device therapies. However, current workflows for both the anatomical and functional twinning phases within CDT generation, referring to the inference of model anatomy and parameters from clinical data, are not sufficiently efficient, robust and accurate for advanced clinical and industrial applications. Our study addresses three primary limitations impeding the routine generation of high-fidelity CDTs by introducing; a comprehensive parameter vector encapsulating all factors relating to the ventricular EP; an abstract reference frame within the model allowing the unattended manipulation of model parameter fields; a novel fast-forward electrocardiogram (Electrocardiogram (ECG)) model for efficient and bio-physically-detailed simulation required for parameter inference. A novel workflow for the generation of CDTs is then introduced as an initial proof of concept. Anatomical twinning was performed within a reasonable time compatible with clinical workflows (<4h) for 12 subjects from clinically-attained magnetic resonance images. After assessment of the underlying fast forward ECG model against a gold standard bidomain ECG model, functional twinning of optimal parameters according to a clinically-attained 12 lead ECG was then performed using a forward Saltelli sampling approach for a single subject. The achieved results in terms of efficiency and fidelity demonstrate that our workflow is well-suited and viable for generating biophysically-detailed CDTs at scale.


Assuntos
Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Simulação por Computador , Coração , Ventrículos do Coração , Humanos
14.
IEEE Trans Biomed Eng ; 68(11): 3410-3416, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33835914

RESUMO

In certain cardiac conduction system pathologies, like bundle branch block, block may be proximal, allowing for electrical stimulation of the more distal His bundle to most effectively restore activation. While selective stimulation of the His bundle is sought, surrounding myocardium may also be excited, resulting in nonselective pacing. The myocardium and His bundle have distinct capture thresholds, but the factors affecting whether His bundle pacing is selective or nonselective remain unelucidated. OBJECTIVE: We investigated the properties which affect the capture thresholds in order to improve selective pacing. METHODS: We performed biophysically detailed, computer simulations of a His fibre running through a septal wedge preparation to compute capture thresholds under various configurations of electrode polarity and orientation. RESULTS: The myocardial capture threshold was close to that of the His bundle. The His fibre needed to intersect with the electrode tip to favor its activation. Inserting the electrode fully within the septum increased the myocardial capture threshold. Reversing polarity, to rely on anode break excitation, also increased the ease of selective pacing. CONCLUSION: Model results were consistent with clinical observations. For selective pacing, the tip needs to be in contact with the His fibre and anodal stimulation is preferable. SIGNIFICANCE: This study provides insight into helping establish electrode and stimulation parameters for selective His bundle pacing in patients.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Bloqueio de Ramo/terapia , Eletrocardiografia , Eletrodos , Frequência Cardíaca , Humanos
15.
J Comput Phys ; 4192020 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-32952215

RESUMO

A key mechanism controlling cardiac function is the electrical activation sequence of the heart's main pumping chambers termed the ventricles. As such, personalization of the ventricular activation sequences is of pivotal importance for the clinical utility of computational models of cardiac electrophysiology. However, a direct observation of the activation sequence throughout the ventricular volume is virtually impossible. In this study, we report on a novel method for identification of activation sequences from activation maps measured at the outer surface of the heart termed the epicardium. Conceptually, the method attempts to identify the key factors governing the ventricular activation sequence - the timing of earliest activation sites (EAS) and the velocity tensor field within the ventricular walls - from sparse and noisy activation maps sampled from the epicardial surface and fits an Eikonal model to the observations. Regularization methods are first investigated to overcome the severe ill-posedness of the inverse problem in a simplified 2D example. These methods are then employed in an anatomically accurate biventricular model with two realistic activation models of varying complexity - a simplified trifascicular model (3F) and a topologically realistic model of the His-Purkinje system (HPS). Using epicardial activation maps at full resolution, we first demonstrate that reconstructing the volumetric activation sequence is, in principle, feasible under the assumption of known location of EAS and later evaluate robustness of the method against noise and reduced spatial resolution of observations. Our results suggest that the FIMIN algorithm is able to robustly recover the full 3D activation sequence using epicardial activation maps at a spatial resolution achievable with current mapping systems and in the presence of noise. Comparing the accuracy achieved in the reconstructed activation maps with clinical data uncertainties suggests that the FIMIN method may be suitable for the patient- specific parameterization of activation models.

16.
SoftwareX ; 11: 100454, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32607406

RESUMO

Advanced cardiac modeling studies rely on the ability to generate and functionalize personalized in silico models from tomographic multi-label image stacks. Eventually, this is used for building virtual cohorts that capture the variability in size, shape, and morphology of individual hearts. Typical modeling workflows involve a multitude of interactive mesh manipulation steps, rendering model generation expensive. Meshtool is software specifically designed for automating all complex mesh manipulation tasks emerging in such workflows by implementing algorithms for tasks describable as operations on label fields and/or geometric features. We illustrate how Meshtool increases efficiency and reduces costs by offering an automatable, high performance mesh manipulation toolbox.

17.
Heart Rhythm ; 17(11): 1922-1929, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32603781

RESUMO

BACKGROUND: His-bundle pacing (HBP) and left bundle pacing (LBP) are emerging as novel delivery methods for cardiac resynchronization therapy (CRT) in heart failure patients with left bundle branch block (LBBB). HBP and LBP have never been compared to biventricular endocardial (BiV-endo) pacing. Furthermore, there are indications of negative effects of LBP on right ventricular (RV) activation times (ATs), but these effects have not been quantified. OBJECTIVE: The purpose of this study was to compare changes in ventricular activation induced by HBP, LBP, left ventricular (LV) septal pacing, BiV-endo, and biventricular epicardial (BiV-epi) pacing using computer simulations. METHODS: We simulated ventricular activation on 24 four-chamber heart meshes inclusive of the His-Purkinje network in the presence of LBBB. We simulated BiV-epi pacing, BiV-endo pacing with left ventricular (LV) lead at the lateral wall, BiV-endo pacing with LV lead at the LV septum, HBP, and LBP. RESULTS: HBP was superior to BiV-endo and BiV-epi in terms of reduction in LV ATs and interventricular dyssynchrony (P <.05). LBP reduced LV ATs but not interventricular dyssynchrony compared to BiV-epi and BiV-endo pacing. RV latest AT was higher with LBP than with HBP (141.3 ± 10.0 ms vs 111.8 ± 10.4 ms). Optimizing AV delay during LBP reduced RV latest AT (104.7 ± 8.7 ms) and led to comparable response to HBP. In case of complete AV block, BiV-endo septal pacing was equivalent to LBP. CONCLUSION: HBP is superior to BiV-epi and BiV-endo. To achieve comparable response to HBP, AV delay optimization during LBP is required in order to reduce RV ATs.


Assuntos
Fascículo Atrioventricular/fisiopatologia , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia , Ventrículos do Coração/fisiopatologia , Função Ventricular Esquerda/fisiologia , Idoso , Bloqueio de Ramo/fisiopatologia , Cateterismo Cardíaco/métodos , Endocárdio , Feminino , Humanos , Masculino
18.
PLoS One ; 15(6): e0235145, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32589679

RESUMO

Computational models of the heart are increasingly being used in the development of devices, patient diagnosis and therapy guidance. While software techniques have been developed for simulating single hearts, there remain significant challenges in simulating cohorts of virtual hearts from multiple patients. To facilitate the development of new simulation and model analysis techniques by groups without direct access to medical data, image analysis techniques and meshing tools, we have created the first publicly available virtual cohort of twenty-four four-chamber hearts. Our cohort was built from heart failure patients, age 67±14 years. We segmented four-chamber heart geometries from end-diastolic (ED) CT images and generated linear tetrahedral meshes with an average edge length of 1.1±0.2mm. Ventricular fibres were added in the ventricles with a rule-based method with an orientation of -60° and 80° at the epicardium and endocardium, respectively. We additionally refined the meshes to an average edge length of 0.39±0.10mm to show that all given meshes can be resampled to achieve an arbitrary desired resolution. We ran simulations for ventricular electrical activation and free mechanical contraction on all 1.1mm-resolution meshes to ensure that our meshes are suitable for electro-mechanical simulations. Simulations for electrical activation resulted in a total activation time of 149±16ms. Free mechanical contractions gave an average left ventricular (LV) and right ventricular (RV) ejection fraction (EF) of 35±1% and 30±2%, respectively, and a LV and RV stroke volume (SV) of 95±28mL and 65±11mL, respectively. By making the cohort publicly available, we hope to facilitate large cohort computational studies and to promote the development of cardiac computational electro-mechanics for clinical applications.


Assuntos
Simulação por Computador , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Telas Cirúrgicas , Função Ventricular Esquerda/fisiologia , Função Ventricular Direita/fisiologia
19.
Heart Rhythm ; 17(8): 1262-1270, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32272230

RESUMO

BACKGROUND: Epicardial pacing increases risk of ventricular tachycardia (VT) in patients with ischemic cardiomyopathy (ICM) when pacing in proximity to scar. Endocardial pacing may be less arrhythmogenic as it preserves the physiological sequences of activation and repolarization. OBJECTIVE: The purpose of this study was to determine the relative arrhythmogenic risk of endocardial compared to epicardial pacing, and the role of the transmural gradient of action potential duration (APD) and pacing location relative to scar on arrhythmogenic risk during endocardial pacing. METHODS: Computational models of ICM patients (n = 24) were used to simulate left ventricular (LV) epicardial and endocardial pacing 0.2-3.5 cm from a scar. Mechanisms were investigated in idealized models of the ventricular wall and scar. Simulations were run with/without a 20-ms transmural APD gradient in the physiological direction and with the gradient inverted. Dispersion of repolarization was computed as a surrogate of VT risk. RESULTS: Patient-specific models with a physiological APD gradient predict that endocardial pacing decreases VT risk (34%; P <.05) compared to epicardial pacing when pacing in proximity to scar (0.2 cm). Endocardial pacing location does not significantly affect VT risk, but epicardial pacing at 0.2 cm compared to 3.5 cm from scar increases it (P <.05). Inverting the transmural APD gradient reverses this trend. Idealized models predict that propagation in the direction opposite to APD gradient decreases VT risk. CONCLUSION: Endocardial pacing is less arrhythmogenic than epicardial pacing when pacing proximal to scar and is less susceptible to pacing location relative to scar. The physiological repolarization sequence during endocardial pacing mechanistically explains reduced VT risk compared to epicardial pacing.


Assuntos
Estimulação Cardíaca Artificial/métodos , Cicatriz/complicações , Simulação por Computador , Ventrículos do Coração/fisiopatologia , Taquicardia Ventricular/terapia , Cicatriz/fisiopatologia , Endocárdio , Humanos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia
20.
Biomech Model Mechanobiol ; 19(3): 1015-1034, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31802292

RESUMO

The left atrium (LA) has a complex anatomy with heterogeneous wall thickness and curvature. The anatomy plays an important role in determining local wall stress; however, the relative contribution of wall thickness and curvature in determining wall stress in the LA is unknown. We have developed electromechanical finite element (FE) models of the LA using patient-specific anatomical FE meshes with rule-based myofiber directions. The models of the LA were passively inflated to 10mmHg followed by simulation of the contraction phase of the atrial cardiac cycle. The FE models predicted maximum LA volumes of 156.5 mL, 99.3 mL and 83.4 mL and ejection fractions of 36.9%, 32.0% and 25.2%. The median wall thickness in the 3 cases was calculated as [Formula: see text] mm, [Formula: see text] mm, and [Formula: see text] mm. The median curvature was determined as [Formula: see text] [Formula: see text], [Formula: see text], and [Formula: see text]. Following passive inflation, the correlation of wall stress with the inverse of wall thickness and curvature was 0.55-0.62 and 0.20-0.25, respectively. At peak contraction, the correlation of wall stress with the inverse of wall thickness and curvature was 0.38-0.44 and 0.16-0.34, respectively. In the LA, the 1st principal Cauchy stress is more dependent on wall thickness than curvature during passive inflation and both correlations decrease during active contraction. This emphasizes the importance of including the heterogeneous wall thickness in electromechanical FE simulations of the LA. Overall, simulation results and sensitivity analyses show that in complex atrial anatomy it is unlikely that a simple anatomical-based law can be used to estimate local wall stress, demonstrating the importance of FE analyses.


Assuntos
Simulação por Computador , Eletrofisiologia/métodos , Átrios do Coração , Algoritmos , Anisotropia , Fenômenos Biomecânicos , Análise de Elementos Finitos , Humanos , Modelos Anatômicos , Pressão , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...